IOP Data Recording and Display When Pickup and Non-volatile Memory (IC171 of BD board) are Replaced

The IOP value labeled on the pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to look at the value on the label of the optical pick-up. When replacing the pick-up or non-volatile memory (IC171 of BD board), record the IOP value on the pick-up according to the following procedure.

Record Precedure:

1.While pressing the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and[ÊÊ]pbutton, connect the power plug to the outlet, and release the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and[ÊÊ]p button.

2.Rotate the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “[Service]”, and press the [YES] button.

3.Rotate the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “lop.Write” (C28), and press the [YES] button.

4.The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.

5.Input the IOP value written on the optical pick-up.

To select the number : Rotate the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob.

To select the digit

: Press the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob.

6.When the [YES] button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).

7.As the adjustment results are recorded for the 6 value. Leave it as it is and press the [YES] button.

8.“Complete!” will be displayed momentarily. The value will be recorded in the non-volatile memory and the display will become “Iop Write”.

9.Press the [REPEAT] button to complete. “Standby” will be displayed.

Display Precedure:

1.While pressing the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and [ÊÊ]p button, connect the power plug to the outlet, and release the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob and [ÊÊ]p button.

2.Rotate the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “[Service]”, and press the [YES] button.

3.Rotate the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± knob to display “lop.Read” (C27).

4.“@@.@/##.#” is displayed and the recorded contents are displayed. @@.@ : indicates the Iop value labeled on the pick-up.

##.# : indicates the Iop value after adjustment

5.To end, press the [ÊÊÊÊÊÊÊÊAMSÊÊÊÊÊÊÊÊ]- ± button or [MENU/NO] button to display “Iop Read”. Then press the [REPEAT] button to display “Standby”.

– 7 –