IOP DATA RECORDING AND DISPLAY WHEN PICKUP AND
The IOP value labeled on the
Record Precedure:
1.While pressing the ENTER/YES button and π button, connect the power plug to the outlet, and release the ENTER/YES button and π button.
2.“TEMP CHECK” will be displayed. Press the MENU/NO button to display “Check”.
3.Rotate the
4.Rotate the
5.The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
6.Input the IOP value written on the optical
To select the digit : Press the CD SYNC/MD WM SYNC button.
7.When the ENTER/YES button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
8.As the adjustment results are recorded for the step 6 value. Leave it as it is and press the ENTER/YES button.
9.“Complete!” will be displayed momentarily. The value will be recorded in the
10.Press the 1/u button to complete. “Standby” will be displayed.
Display Precedure:
1.While pressing the ENTER/YES button and π button, connect the power plug to the outlet, and release the ENTER/YES button and π button.
2.“TEMP CHECK” will be displayed. Press the MENU/NO button to display “Check”.
3.Rotate the
4.Rotate the
5.“@@.@/##.#” is displayed and the recorded contents are displayed. @@.@ : indicates the Iop value labeled on the
##.#: indicates the Iop value after adjustment
6. To end, press the CD SYNC/MD WM SYNC button or MENU/NO button to display “Iop Read”. Then press the 1/u button to display “Standby”.
– 7 –