Fan

The fan will automatically start when heat rises from range surface units or burners and when convection, high mix, low mix or the broil settings are used. This protects the microwave oven from excessive tem- perature rise. The fan will stay on until the temperature decreases. It cannot be turned off manually during this time.

For other uses, select either high or low speed.

PRECAUTIONS FOR PROPER USE:

1.DO NOT leave range unattended while using high temperatures. Automatic fan may start and provide excessive air to the surface units. This may cause spattering or boilover.

2.Avoid burning food.

3.Keep grease filters clean.

Light

1.To replace light bulbs, first disconnect power to the oven at the circuit breaker panel or by unplugging.

2.To release cover remove the screw on the light cover. (See illustration.)

3.Replace bulbs only with equivalent watt bulbs available from a Sharp Authorized Servicer or parts distributor. Bulbs are also available at most hardware stores or lighting centers. DO NOT USE A BULB LARGER THAN 30 WATTS.

4.Close light cover and secure with screw removed in step 2.

CAUTION: Light cover may become very hot. Do not touch glass when light is on. Do not use light for long time use such as a night light.

Charcoal Filter

Charcoal Filter, Sharp Part Number RK-220 is used for Non-vented, recirculated installation. The filter should be changed every 6 to 12 months depending on use.

1.Disconnect power to the oven at the circuit breaker panel or by unplugging.

2.Remove 3 screws that secure louver.

3.Remove louver by inserting flat edge screwdriver over each tab pressing the tab down and moving louver away from unit.

4.Pull the louver away from the oven.

5.Remove 2 screws that secure the sensor duct cover.

6.Remove the sensor duct cover.

7.Remove old charcoal filter (if one is installed).

8.Slide new Charcoal Filter into position on the sup- port tabs.

9.Reattach sensor duct cover and secure with 2 screws.

10.Push louver back into place and gently snap tabs into place by hand (engaging both the bottom and top tabs) and replace the 3 screws to secure louver.

Sensor duct cover

Charcoal filter

Light cover

Light bulbs

 

Screw