![](/images/new-backgrounds/1118660/11866043x1.webp)
BBV Rx 100 Interface Receiver
Addendum to manual for the following domes:
Mark Mercer 150 and D250/500 series
Rx100 software RX1_M1V6
Application Notes
Variable speed Pan/Tilt. Zoom/Focus override, Iris override 16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 – 4
2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.
Advanced Features | Tx400 | Tx1000 | Tx1500 | DM Mux/DS/DSL/DS2/BX2 etc |
Pan | ‘#’ 1 | '#' WASH | 1 ‘#’ | *889 002 or *889 10 10 2 |
Dome Reset | ‘#’ 4 | ‘#’ LIGHTS | 4 ‘#’ | *889 005 or *889 10 10 5 |
A slow preset patrol can be started by pressing AUTOPAN. The preset dwell is fixed at 20 seconds with a dome speed of 1.
RS485 control of dome using the following connections:
Rx100 | Description | Dome | 6 pin connector |
TX/RX- | RS485 B Pin 4 | (RED) | |
TX/RX+ | RS485 A Pin 3 | (GREEN) |
Notes:
The alarm output relay opens for approx 5 seconds upon power up and following a local alarm activation.
Links Function
J6/3,4,5 Select datum operation,
Only operational whilst the dome is not running a patrol.
Rx100 installation manual V1.17 29 Aug 08.doc | Page 22 |