Sony RX100 manual Cable Connection Method

Models: RX100

1 40
Download 40 pages 37.04 Kb
Page 7
Image 7

CABLE CONNECTION METHOD

Fig. 1: cage clamp connectors

The cage clamp PCB terminal block is a simple-to-use method of attaching cables to PCBs quickly and easily. Prepare cables as follows:

Use only cable between 0.08 and 2.5 mm²

Strip the cable to a length of 5 to 6 mm (0.23 in) The correct method of attachment is as follows:

1. Press down the relevant terminal block lever with a suitable screwdriver;

2. Insert wire;

3. Remove screwdriver.

The procedure for detaching wires is the reverse of the 3 attachment steps, ensuring that power is disconnected before starting.

CABLING RECOMMENDATIONS FOR THE Rx100 INTERFACE.

Although BBV do not specify any particular type, manufacturer or supplier of cables, the following ESD Electronic Services (01279 626777) cables have been used successfully for production and testing:

ESD Part Number:

Description:

0222586G

Coax Cable (Minimum Specification)

(100 m)

RG59B/U ESD radio frequency coax cable to BS2316 and MIL-C-17

 

1/0.58mm copper-covered steel wire conductor with solid polythene dielectric, bare

 

copper wire braid and PVC sheath

 

Characteristic impedance: 75 Ohm

 

Capacitance: 22pF/ft

020966D

Orange-Coloured Lighting Output Power Cable (1000 w)

(100 m)

3183Y PVC-insulated, 3-core cable

 

1.25mm²

40/0.2mm annealed copper conductor

 

Current rating: 13 amp

0140467H

20mA Twisted Pair Cable (Minimum Specification)

(100 m)

British Telecom spec CW 1308

 

2-core 1/0.5mm PVC-insulated

 

Maximum

conductor resistance at 20 degrees Celsius: 97.8 ohms/km

Rx100 installation manual V1.17 29 Aug 08.doc