Sony RX100 manual RS485 B

Models: RX100

1 40
Download 40 pages 37.04 Kb
Page 37
Image 37

BBV Rx100 Interface Receiver

Addendum to manual for the following domes:

Vista PowerDome

Rx100 software RX1_V3V2

Application Notes

The RX 100 provide the following functionality when controlling the above mentioned dome

Variable speed Pan/Tilt.

Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out.

16 Full scene presets.

2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 02) Learned tour playback using AUTOPAN key.

5 minute datum/park driving to preset 1 or dome’s TOUR 2. Disabled by removing link J6/1-2 Program up to 16 privacy zones

Advanced Features

Tx400

Tx1000

Tx1500

DM DS/DS2/BX2 Mux

 

Display MENU

‘#’ 1

'#' WASH

1 ’#’

*889 002 or *889 10 10 2

ENTER in MENU

‘#’ 2

'#' WIPE

2 ’#’

*889 003 or *889 10 10 3

ESC in MENU

‘#’ 3

'#' AUTOPAN

3 ’#’

*889 004 or *889 10 10 4

The dome and Rx100 are linked using RS485 for control and video for the camera signal.

Rx100

Description

Dome connection

J3-C1

TX-/B

RS485 B -

J3-C2

TX+/A

RS485 A +

Notes:

The dome address must be set at 1 for all the cameras that are controlled using a Rx100. Check with the dome manual if you have any doubts.

The alarm output relay opens for approx 5 seconds upon power up and following any active alarm input.

If the learned tour playback is running, start patrol 1 is inhibited. The dome will be driven to a preset following an alarm activation. 60 seconds after alarm, the learned tour will restart. A manual goto preset and lens control will stop the tour leaving the AUTOPAN led on until the next manual pan command.

J6 Links

J6/1-2 fitted to enable the 5 minute datum mode. After 5 minutes of inactivity the dome will be driven to either preset 1 or the dome’s TOUR 2 is started depending upon link J6/3,4,5. J6/4-5 fitted = goto preset 1, J6/3-4 fitted = start dome TOUR 2.

The dome’s TOUR 2 must be programmed from within the domes menu. Please refer to the dome manual for details.