Preparation

6 Click on the camera in the list to which you want to assign a new IP address.

The network settings for the selected camera are displayed.

7 Set the IP address.

To obtain the IP address automatically from a DHCP server:

Select Obtain an IP address automatically.

The IP address, Subnet mask and Default gateway are assigned automatically.

To specify the IP address manually:

Select Use the following IP address, and type the IP address, Subnet mask and Default gateway in the relevant boxes.

Note

When you select Obtain an IP address automatically, make sure that the DHCP server is operating on the network.

8 Set the DNS server address.

To obtain the DNS server addresses automatically:

Select Obtain DNS server address automatically.

To specify the DNS server addresses manually: Select Use the following DNS server address, and type the Primary DNS server address and Secondary DNS server address in the relevant boxes.

Note

The Third DNS server address and Fourth DNS server address are invalid for this camera.

9 Set the HTTP port No.

Normally, select 80 for the HTTP port No. To use another port number, type the port number between 1024 and 65535 in the text box.

10 Type the Administrator name and Administrator password.

The factory settings of both items are “admin.”

Note

You cannot change the Administrator name and Administrator password in this step. To change these items, see “Setting the User — User Menu” on page 56.

11 Confirm that all items are correctly set, then click OK.

8 Assigning the IP Address to the Camera