System Configuration

System example when operating the SRP-X700P from the REMOTE PARALLEL terminal

The REMOTE PARALLEL terminal of the SRP-X700P is shipped from the factory with the default setting on the premise of the external operation panel as described below.

START VHS DV

Camera

DVD PC1 PC2

MIC

AV

Stand

FINISH

 

 

 

 

EMG STOP

 

 

 

 

START button (SCENE No. 1 recall): Sets OUTPUT7 and OUTPUT9 to ON to lower the screen, to close the curtain, to darken the illumination and to start presentation.

FINISH button (SCENE No. 2 recall): Sets OUTPUT8 and OUTPUT10 to ON to raise the screen, to open the curtain, to turn on the illumination and to end the presentation.

EMG STOP button (SCENE No. 3 recall): Sets OUTPUT7 through OUTPUT10 to OFF to stop moving the screen and the curtain, and to turn on the illumination.

Selector block: Switches the LINE4 INPUT terminals A through F.

MIC volume control: Controls the microphone sound volume.

AV volume control: Controls sound volume of the AV equipment.

SRP-X700P REMOTE PARALLEL terminal

External operation panel

 

D-sub 25-pin connector

 

 

Pin No. Terminal name

Function name

 

1

GND

GND

 

2

INPUT1

VHS selection

VHS VCR selector button

3

INPUT2

DV selection

DV VCR selector button

4

INPUT3

Camera selection

Picture presentation camera selector button

5

INPUT4

DVD selection

DVD selector button

6

INPUT5

PC1 selection

PC1 selector button

7

INPUT6

PC2 selection

PC2 selector button

8

INPUT7

START

START (presentation start) button

9

INPUT8

FINISH

FINISH (presentation finish) button

10

INPUT9

EMG STOP

Emergency stop button

11

INPUT10

Microphone sound volume

Microphone sound volume control (10kB-curve)

12

INPUT11

AV equipment sound volume

AV equipment sound volume control (10kB-curve)

13

INPUT12

———

40mA or less

14

GND

GND

 

15

OUTPUT1

VHS selection tally

VHS VCR selection LED

16

OUTPUT2

DV selection tally

DV VCR selection LED

17

OUTPUT3

Camera selection tally

Picture presentation camera selection LED

18

OUTPUT4

DVD selection tally

DVD selection LED

19

OUTPUT5

PC1 selection tally

PC1 selection LED

20

OUTPUT6

PC2 selection tally

PC2 selection LED

21

OUTPUT7

Lowers the screen.

LED

 

22

OUTPUT8

Raises the screen.

DC 24V or less

23

OUTPUT9

Close the curtain/turn off illumination.

 

24

OUTPUT10

Open the curtain/turn on illumination.

 

25

GND

GND

 

Precaution on the environment interface box specifications

 

 

 

 

 

Lowers the screen.

 

Screen

The REMOTE PARALLEL output terminal provides the open-collector output of

 

 

 

 

 

Raises the screen.

 

 

 

 

 

 

 

interface box

 

alternate operation. It means that the output terminal keeps outputting the ON signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

after an output command is issued to operate the environment equipment by using

 

 

 

 

 

Closes the curtain.

 

 

 

 

 

 

 

 

 

 

 

scene recall and others, regardless of the operating condition of the environment

 

 

 

 

 

 

Curtain

 

equipment. The environment equipment motors should be stopped when you want to

 

 

 

 

 

Opens the curtain.

 

 

 

 

 

 

 

 

interface box

 

stop raising or lowering the screen or curtain, by the Interface Box.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Emergency Stop signal turns off the output signals at the OUTPUT7 to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT10 terminals.

 

 

 

 

 

 

 

 

 

 

 

Turns off illumination.

 

Illumination

 

Please create an Interface Box that stops moving the screen and the curtain, and turns

 

 

 

 

Turns on illumination.

 

 

 

 

 

 

 

interface box

 

on illumination when the output terminals are turned off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example of controlling the environment equipment by scene recall operation

 

 

 

OUTPUT 7,9

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

name

OUTPUT 8,10

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen

Curtain Illumination

 

 

 

 

 

 

 

 

 

EMG STOP

 

 

 

Raise

Open

Bright

 

 

 

 

 

 

 

 

 

 

 

Environment

 

 

 

 

 

 

 

 

 

(SCENE No. 3 recall)

 

 

equipment

Stop

Bright

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lower

Close

Dark

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turning on

START

 

FINISH

 

 

 

START

 

 

 

 

 

the power (SCENE No. 1 recall)

(SCENE No. 2 recall)

(SCENE No. 1 recall)

 

14