Roberts Gorden HE-80 Gas Connection with Flexible Gas Hose CORRECT POSITIONS, in product damage

Models: HE-125 HE-150 HE-100 HE-40 HE-175 HE-80 HE-60

1 72
Download 72 pages 53.49 Kb
Page 50
Image 50

HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

FIGURE 23: Gas Connection with Flexible Gas Hose

CORRECT POSITIONS

 

 

 

CAUTION

 

 

 

Product Damage Hazard

Shut-Off Valve (included with gas hose) must

Hold gas nipple securely with pipe wrench

be parallel to burner gas inlet. The 3" (8 cm)

displacement shown is for the cold condition.

when attaching gas hose.

This displacement may reduce when the

Failure to follow these instructions can result

system is fired.

 

 

 

 

 

in product damage.

 

 

 

Vertical

 

 

 

(as shown left)

 

3" (8 cm)

 

12"

max. displacement

45°

 

Side View

(30 cm)

 

 

 

 

 

Alternate

 

 

 

positions

 

 

 

okay

 

 

 

Horizontal

Flexible Gas Hose

 

End View

36" (91 cm) length

Heater Movement

 

 

INCORRECT POSITIONS (WRONG INSTALLATION)

Heater Movement

Heater Movement

Heater Movement

 

Heater Movement

 

 

 

 

 

 

 

 

 

 

Description

Part Number

 

 

 

3/4" Flexible Stainless Steel Gas Hose (US Models)

91412204

 

 

 

 

 

 

 

 

3/4" Rubber Type 1 Gas Hose (Canadian Models)

91412207

 

 

 

 

 

 

 

 

 

 

44

Page 50
Image 50
Roberts Gorden HE-80 Gas Connection with Flexible Gas Hose CORRECT POSITIONS, Hold gas nipple securely with pipe wrench