SECTION 6: HEATER INSTALLATION

6.1 Outdoor Mounting

The heater is meant for stationary mounting in all sit- uations and should not be suspended from any struc- ture which may become mobile or from any organic structures such as trees. Clearances to combustibles must be maintained in all cases; do not install heat- ers in a location such as a parking area, where a vehicle with a painted or non-metallic uppersurface,

may be parked within the clearances to combustibles.

The bottom of the combustion air inlet shall not be less than 12" (30 cm) above a surface which could support snow, ice, or debris. See Page 17, Figure 15.

FIGURE 15: Critical Hanger Placement (Outdoor Installation)

Typical Outdoor Suspension Details

I-BeamUnistrut

Beam Clamp

24" (60 cm) Minimum

Locknut

Fully Closed

Turnbuckle

(Not Included)

Angle Iron or

Metal Channel

wall

Spring clip or other closed device capable

of supporting at least 75 lbs (33 kg).

Eyebolt

17