HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

SECTION 5: MAJOR COMPONENTS

FIGURE 13: Major Component Descriptions

Burner with Tube Gasket

Reflector

Must be installed with the

(Stainless Steel

flame observation

or Aluminum)

window facing down.

Alternate

 

overlap as shown

 

on overview and on Page

 

19, Figure 17. Minimum

 

overlap is 6" (16 cm).

Burner Tube

Supplied in 10' (3 m) lengths. Burner tube is always the first tube after the burner.

Tube and Reflector Hanger with Clamp Package Position this hanger no more than 4" (10 cm) away from the burner.

Tube and Reflector Hanger

Vent Cap Attach at flue end and air inlet with vent adapter, where required.

Tube

Heat Treated

Aluminized tube supplied in 10' (3 m) lengths.

Coupling Assembly with Lock

Reflector End Cap Punch out center section to accommodate tube.

Suspend system from these hangers.

Reflector Support Strap & Wire Form

Vinyl Coated Flex Gas Line with Shut Off Cock

Vent Adapter

Turbulator

Turbulator must be installed in the last standard section of tube.

Turbulator is not required on the HE-125/150/175. For installation see Page 22, Section 6.5.