46US
D:\NORM'S JOB\SONY HA\SO120031\STR-DA1800ES_PMRF
02\4428194122_USFR\US04GET_STR-DA1800ES-CEL.fm masterpage: Left
STR-DA1800ES
4-428-194-12(2)
3Press V/v repeatedly to select

“Auto Cal.”, then press or b.

4Press B/b repeatedly to select

“Start”, then press .

5Press to select “START”.
6The measurement starts in five

seconds.

The measurement process will take
approximately 30 seconds with a test
tone.
When the measurement ends, a beep
sounds and the screen switches.
Note
If an error code appears on the screen, see
“Message list after Auto Calibration
measurement” (page 48).
7Press V/v repeatedly to select

the item you want, then press

.
Retry:
Performs the Auto Calibration again.
Save:
Save the measurement results and exits
the setting process.
Warning:
Displays warning related to the
measurement results. See “Message list
after Auto Calibration measurement”
(page 48).
Exit:
Exits the setting process without saving
the measurement results.
8Save the measurement result.
Select “Save” in step 7.
Notes
The A.P.M. (Automatic Phase Matching)
function is activated after you save the
measurement result.
The A.P.M. function does not work in the
following cases.
The calibration type is set to “Off” when
using the “Cal. Type” Auto Calibration
(page 47).
When Dolby TrueHD or DTS-HD signals
with a sampling frequency of more than
48 kHz are being received.
9Press B/b repeatedly to select

“Cal. Type”, then press .

Full Flat:
Makes the measurement of frequency
from each speaker flat.
Engineer:
Sets to “the Sony listening room
standard” frequency characteristics.
Front Reference:
Adjusts the characteristics of all the
speakers to match the characteristics of
the front speaker.