The change becomes effective the next time you turn on the unit by setting the POWER switch to ON.

4-bFor the portable diversity tuner (URX-P1)

Leave the tuner for about 10 seconds until the time indication stops flashing and the setting is stored in memory.

Setting the RF outputlevel

The procedure below is the same for all UWP series transmitters (UTX-B1/H1).

You can select an RF output level of H (30 mW) or L (5 mW) in setting mode. Set the RF output level to L (5 mW) for simultaneous operation of multiple channels, and set it to H (30 mW) for long-distance operation.

1 Turn on the transmitter while pressing down the SET button.

2 Press the SET button repeatedly until the RF output level indication appears in the display section.

3 Press the + button to select H (30 mW), or press the – button to select L (5 mW).

4 Set the POWER switch to OFF to complete the setting, or press the SET button to set other items.

The results are stored in memory. The change becomes effective the next time you turn on the transmitter by setting the POWER switch to ON.

Setting the monitor level (portable diversity tuner (URX-P1) only)

You can set the monitor level for monitoring the tuner output within the range of 01 to 24.

1 While the parameters on the display section are not flashing, press the + or – button once. The monitor level indication appears in the display section.

2 Press the + button to increase the monitor level, or press the – button to decrease the level. When you leave the tuner for about two seconds or more, current monitor level setting is stored in memory and the normal display resumes. Note that monitor level setting is effective after you turn off the tuner, then turn it on again.

41