Note
After removing the air filter, do not touch the fan inside the projector.
10 Attach the air filter cover.
11 Wipe dust off the Ventilation holes (intake) with a soft cloth.
Ventilation holes (intake)
Note
The projector will not turn on unless the air filter cover is securely closed.
12 Place the project back on its original position.
Place a new air filter.
9

13 Turn on the projector, then select the desired setting item on the Setup menu. The menu screen below will be appeared.

14

15

Select “Yes”.

Others

Select “OK”.

Caution

Do not put your hands into the lamp replacement slot, and do not allow any liquid or other objects into the slot to avoid electrical shock or fire.

Notes

Be sure to use an LMP-H160 Projector Lamp for replacement. If you use lamps other than the LMP-H160, the projector may malfunction.

Be sure to turn off the projector and unplug the power cord before replacing the lamp, then check the ?/1 (On/standby) indicator has already been turned off.

The projector will not turn on unless the lamp is securely installed in place.

The projector will not turn on unless the lamp cover are securely closed.

To cancel a message displayed on the screen, press either the button on the remote control or the one on the control panel on the projector.

Note

The lamp contains mercury. The disposal rules for used fluorescent tubes depend on where you live. Follow the waste disposal policy in your area.

57