Control of IIDC Standard Features

Before transmitting the control command, check the variable ranges of settings and if there is an automatic mode for each feature.

As the variable ranges of the settings vary with video modes for the Pan and Tilt features, be sure to check them if the video mode is changed.

Address

Data

Bit

 

 

 

 

 

F0F00500h

890003FFh

0

This feature exists.

(Brightness)

 

 

 

 

4

The value can be read out.

 

 

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0

 

 

 

 

 

 

20-31

Max. 1023

 

 

 

 

F0F00504h

891003FFh

0

This feature exists.

(AutoExposure)

 

 

 

 

4

The value can be read out.

 

 

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 256

 

 

 

 

 

 

20-31

Max. 1023

 

 

 

 

F0F00508h

89000007h

0

This feature exists.

(Sharpness)

 

 

 

 

4

The value can be read out.

(Black and white models

 

 

 

 

only)

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0

 

 

 

 

 

 

20-31

Max. 7

 

 

 

 

F0F0050Ch

9B7009FFh

0

This feature exists.

(WhiteBalance)

 

 

 

 

4

The value can be read out.

(Color models only)

 

 

 

 

 

 

6

Auto setting can be selected.

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 1792

 

 

 

 

 

 

20-31

Max. 2559

 

 

 

 

F0F00510h

897009FF

0

This feature exists.

(Hue)

 

 

 

 

4

The value can be read out.

(Color models only)

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 1792

 

 

 

 

 

 

20-31

Max. 2559

 

 

 

 

F0F00514h

890401FF

0

This feature exists.

(Saturation)

 

 

 

 

4

The value can be read out.

 

 

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 64

 

 

 

 

 

 

20-31

Max. 511

 

 

 

 

F0F00518h

89000003h

0

This feature exists.

(Gamma)

 

 

 

 

4

The value can be read out.

 

 

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0

 

 

 

 

 

 

20-31

Max. 3

 

 

 

 

Control