Control

For offset address 434h, the length of the UnitDependentInfo is 0Bh Quadlets.

CommandRegsBase is the base address of the camera control register.

F0000000h + 3c0000h × 4 = F0F00000h

The offset address of VendorNameLeaf is required to be 43Ch + 00000Ah × 4 = 464h

The offset address of ModelNameLeaf is required to be 440h + 00000Dh × 4 = 474h

Unit_sub_sw_version conforms to IIDC Standards, Version 1.31.

Vendor_unique_info 0 to Vendor_unique_info 3 are terms of information that the vendor of the camera can define. The meanings in this camera are as follows:

Vendor_unique_info_0 is the firmware version.

Vendor_unique_info_1 is the hardware version.

Vendor_unique_info_2 is the link version.

Vendor_unique_info_3 is the serial number of the camera.

VendorNameLeaf

 

Offset

0-7

 

8-15

16-23

 

24-31

 

 

 

 

 

 

 

 

 

 

Vender Name Leaf

464h

0003

 

 

CRC

 

 

 

 

 

 

 

 

 

 

 

468h

00

 

00

00

 

00

 

 

 

 

 

 

 

 

 

 

 

46h

00

 

00

00

 

00

 

 

 

 

 

 

 

 

 

 

 

470ch

53

 

4F

4E

 

59

SONY

 

 

 

 

 

 

 

 

 

For offset address 464h, the length of the VendorNameLeaf is 3 Quadlets.

The subsequent 8 bytes are fixed at 00.

After that, the four characters for “SONY” are entered.

ModelNameLeaf

 

Offset

0-7

 

8-15

16-23

 

24-31

 

 

 

 

 

 

 

 

 

 

Model Name Leaf

474h

0005

 

 

CRC

 

 

 

 

 

 

 

 

 

 

 

478h

00

 

00

00

 

00

 

 

 

 

 

 

 

 

 

 

 

47ch

00

 

00

00

 

00

 

 

 

 

 

 

 

 

 

 

 

480h

58

 

43

44

 

2D

XCD-

 

 

 

 

 

 

 

 

 

 

484h

56

 

36

30

 

43

V60C

 

 

 

 

 

 

 

 

 

 

488h

52

 

00

00

 

00

R···

 

 

 

 

 

 

 

 

 

For offset address 474h, the length of the ModelNameLeaf is 5 Quadlets.

The subsequent 8 bytes are fixed at 00.

After that, the model name is entered.