Actual control can be carried out by setting registers from F0F00800 onward.

dddindicates the control value expressed as a 12 bit hexadecimal number.

xxx indicates that any setting made will be ignored.

Brightness control

Address

Data

 

 

 

 

F0F00800

82000ddd

Adjusts the black level.

 

 

 

AE reference control

Address

Data

 

 

 

 

F0F00804

82000ddd

Sets the AE reference value.

 

 

 

Sharpness control

Address

Data

 

 

 

 

F0F00808

82000000

Sets to the soft image quality.

 

 

 

 

82000007

Sets to the sharp image quality.

 

 

 

White balance control

Address

Data

 

 

 

 

F0F0080C

82BBBRRR

Adjusts the white balance

 

 

manually.

 

 

 

 

83xxxxxx

Adjusts the white balance

 

 

automatically.

 

 

 

 

86xxxxxx

Perform the one-push auto

 

 

white balance function.

 

 

 

Hue (G level) control

Address

Data

 

 

 

 

F0F00810

82000ddd

Sets the green video level.

 

 

 

Saturation control

Address

Data

 

 

 

 

F0F00814

82000ddd

Adjusts the color intensity.

 

 

 

Gamma control

Address

Data

 

 

 

 

F0F00818

82000000

Sets Gamma to OFF.

 

 

 

 

82000001

Reverses the black and white.

 

 

 

 

82000002

Sets the gamma curve

 

 

equivalent to 0.7.

 

 

 

 

82000003

Sets an optional gamma curve

 

 

by a user. (See “LUT.”)

 

 

 

Shutter (exposure time) control

Address

Data

 

 

 

 

F0F0081C

82000ddd

Controls shutter using the

 

 

manually set relative value.

 

 

 

 

83000xxx

Sets the shutter control to

 

 

AUTO.

 

 

 

 

C2000xxx

Controls shutter using the

 

 

absolute value.

 

 

 

F0F00978h

Determines

After F0F0081C has been set

(To obtain

the optional

to the absolute value control,

this address,

value using

set the exposure time using

see “The

the 32-bit

this register.

formula for

floating-

 

absolute

point format.

 

value shutter

 

 

control

 

 

register

 

 

address” on

 

 

page 24.)

 

 

 

 

 

Gain control

Address

Data

 

 

 

 

F0F00820

82000ddd

Set Gain manually.

 

 

 

 

83000xxx

Set Gain to AUTO.

 

 

 

Trigger control

Address

Data

 

 

 

 

F0F00830

82000000

Sets to Hardware Trigger

 

 

Mode0.

 

 

 

 

82010000

Sets to Hardware Trigger

 

 

Mode1.

 

 

 

 

820E000d

Sets to Hardware Trigger

 

 

Mode14.

 

 

 

 

820F000d

Sets to Hardware Trigger

 

 

Mode15.

 

 

 

 

82E00000

Sets to Software Trigger

 

 

Mode0.

 

 

 

 

82E10000

Sets to Software Trigger

 

 

Mode1.

 

 

 

 

82EE000d

Sets to Software Trigger

 

 

Mode14.

 

 

 

 

82EF000d

Sets to Software Trigger

 

 

Mode15.

 

 

 

F0F0062C

80000000

Outputs a software trigger. In

 

 

Trigger Mode0, automatically

 

 

resets to 0 when exposure

 

 

ends.

 

 

 

 

00000000

In Trigger Mode1, ends

 

 

exposure if “0” is set.

 

 

 

Trigger Delay control

Address

Data

 

 

 

 

F0F00834

82000ddd

Sets Trigger Delay.

 

 

 

Control

23