ADJUSTMENTS | MODEL 300 RESTAURANT RANGES |
ADJUSTMENTS
ADJUSTMENTS
!WARNING
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with information listed on the serial plate.
GAS PRESSURE REGULATOR
The pressure regulator is factory set at 4" W.C. for natural gas and 10" W.C. for propane gas. To check the manifold pressure:
1.Turn all thermostats and burner valves to “OFF” position.
2.Turn main gas valve to entire unit off.
3.Remove valve panels and locate 1/8" plug in manifold.
4.Remove plug and install a fitting appropriate to connect a manometer.
5.Turn on main gas to unit and light pilots.
6.Turn all burners and ovens to full “ON” position and read manometer.
7.If manometer does not read 4" W.C. for natural gas, or 10" W.C. for propane gas, adjust regulator (if gas pressure is O.K. go to Step 10).
8.Remove cap from top of regulator.
9.With a screwdriver rotate regulator adjustment screw “clockwise” to increase, or “counterclockwise” to decrease, pressure until manometer shows correct reading.
10.Repeat steps 1 and 2.
11.Remove manometer fitting and replace plug in manifold.
12.Repeat step 5.
13.Replace valve panels.
TOP PILOTS:
These are located under
Outage is often caused by an unstable flame due to
Often, in an effort to improve ignition, the pilots are increased too much and result in this unstable condition.
These pilots are adjusted by inserting the blade of a screwdriver into the slot on the small valve, located on the manifold. The maximum flame size is approximately 3/4" with a slight yellow tip. The first indication of