MODEL 300 RESTAURANT RANGES

TROUBLESHOOTING

CONVECTION OVEN BLOWER

DOES NOT RUN

REMOVE THE MAIN POWER

SOURCE. UNPLUG OR DISCONNECT CIRCUIT BREAKER.

Remove the control knobs from the

range.

CAUTION! WIRING BEHIND THE

PANEL OF THE NEXT STEP.

Move a DVM probe to the center terminal of the

switch wires 1 and 2.

Check the voltage specified by the Serial Plate located behind the oven valve cover panel.

Connect the main power supply.

 

Is the voltage

 

Yes

No

as specified?

Remove the upper valve panel cover screws and tilt the panel forward to expose the back of blower switch.

Remove the protective cover from

over the switch.

Check that the wires and terminals

are secure on the switch.

Refer to schematic P/N’s:

1181101 for 120V,

1181102 for 208/240V.

Place a DVM on the end terminals of the blower switch wires 1 and 3.

Reinstall the switch

cover and valve

panel.

Turn on the power

switch.

Open the oven door.

If the blower runs, the Door Switch is wired wrong.

Disconnect the main

power supply.

Disconnect the main

power supply.

Check the facility's

power supplies.

Reinstall the switch

cover and valve

panel.

Connect the main

power supply.

Test oven.

Place switch in on position.

No Continuity? Yes

Replace the switch.

Reinstall the switch cover and

valve panel.

Test blower.

Open the kick panel by raising it

and tilting the top outward.

Check that one wire is connected

to the (common), 90° bottom

terminal of the switch.

Move the other wire to the lower leg (N.O.) on the side of the switch.

Continues on following page.

TROUBLESHOOTING

OPERATORS MANUAL 1182298 REV 3

PAGE 39