TROUBLESHOOTING

MARATHONER GOLD & SILVERSTAR GAS CONVECTION OVENS TROUBLESHOOTING

TROUBLESHOOTING

!WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.

NOTICE

Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified technician, or if other than genuine Southbend replacement parts are installed.

In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with information listed on the serial plate. The serial plate is located inside the lower front panel.

PERFORMANCE STANDARD

The typical time for the oven to heat from 75°F to 350°F is 5 to 6 minutes for ovens using natural gas, and 7 to 8 minutes for ovens using propane.

The burners should come on when the actual oven temperature drops to 10°F below the temperature setting.

INTERPRETING DISPLAYED ERROR CODES

Programmable and Rack Timer models are able to detect some problems that might occur. If the control panel display is showing a letter “F” followed by a number, consult the following table to determine the problem and appropriate corrective action.

Symptom

Possible Cause

Check or Replace

Display shows F1

Bad temperature controller.

Display shows F2

Oven interior maximum temperature

 

exceeded.

Display shows F3

Open temperature probe.

 

 

Display shows F4

Shorted temperature probe.

 

 

Display shows F5

Bad temperature controller.

 

 

Display shows F6

Bad temperature controller.

 

 

Display shows F7

Total cook time in a program exceeds 24

 

hours (programmable models only).

Display shows F8

Bad temperature controller.

Replace temperature controller.

Check whether gas valve is stuck open. If not, replace temperature controller.

Check connection. If connection is OK, replace probe. Check probe wires. If wires are not shorted, replace probe. Replace temperature controller.

Replace temperature controller.

Change program so that total cook time does not exceed 24 hours.

Replace temperature controller.

TROUBLESHOOTING

OPERATORS MANUAL 1181887 REV 3

PAGE 41