NOTICE

These installation procedures must be followed by qualified personnel or warranty will be void.

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,or the Propane Installation Code CAN/CGA- B149.2, as applicable, including:

1.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).

2.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).

NOTICE

EXHAUST FANS AND CANOPIES: It is recommended that the cheese melter be installed under a ventilation hood. Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by warranty.

NOTICE

In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods shall comply with 248 CMR interlocking requirements.

STEP 1: UNPACKING

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim must be made with the delivering carrier.

Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply the necessary forms.

A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all contents plus all packing material.

Do the following:

1.Cut the banding straps and remove the corrugated cardboard surrounding the cheese melter. If legs were shipped in the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or labels attached to the cheese melter until the cheese melter is installed and working properly.

2.Cut the banding strap holding the cheese melter to the wooden skid.

3.If installing the cheese melter over a range, go to Step 2a. If installing the cheese melter on a wall, go to Step 2b.

If installing the cheese melter on legs for countertop use, go to Step 2c.

OWNERS MANUAL 1186531 REV 2 (09/11)

PAGE 13 OF 24

Page 13
Image 13
Southbend P24-CM manual Installation, Unpacking

P24-CM specifications

The Southbend P24-CM is a premier commercial gas range designed to meet the demanding needs of professional kitchens. This range is celebrated for its robust construction, thoughtful design features, and efficient cooking capabilities, making it a favorite among chefs and cooks in various culinary settings.

One of the standout features of the P24-CM is its powerful burner system. It comes with four open burners that provide precise temperature control. Each burner is capable of generating up to 30,000 BTUs, allowing chefs to quickly boil, sauté, or simmer food as needed. This versatility is essential in a busy kitchen where time is of the essence.

The P24-CM is constructed from stainless steel, ensuring durability and resistance to the wear and tear of a bustling culinary environment. The stainless steel finish not only enhances the range's aesthetic appeal but also makes it easy to clean and maintain. Its modular design means it can fit seamlessly with other kitchen equipment and promote a more efficient workspace.

Another key feature of the Southbend P24-CM is its 24-inch depth, providing a compact solution for kitchens with limited space. Despite its smaller footprint, this range does not compromise on performance or functionality. The integrated grease tray and removable drip tray streamline the cooking process by simplifying cleanup, ensuring that chefs can focus on their culinary creations rather than maintenance.

The Southbend P24-CM also features a cast iron griddle option, which adds versatility in cooking methods. This heavy-duty griddle allows for evenly distributed heat, making it ideal for cooking a variety of foods, from pancakes to sautéed vegetables. Moreover, the range comes equipped with a heavy-duty oven that operates with an adjustable thermostat, providing consistent baking and roasting results.

The ignition system on the P24-CM is designed for safety and ease of use. It features a pilotless ignition that starts with just the push of a button, minimizing the risk of gas leaks and providing a quick start-up for busy kitchen operations.

In summary, the Southbend P24-CM is an exceptional gas range that combines power, durability, and space efficiency. With its high BTU burners, robust construction, and innovative features, it is tailored to meet the rigorous demands of professional kitchens while offering chefs the tools they need to create culinary masterpieces.