For Machines Mfg. Since 8/09 | P R E P A R A T I O N | Model SB1023 |
Power Connection
Electrocution or fire may occur if machine is ungrounded, incorrectly connected to power, or connected to an undersized circuit. Use a qualified electrician to ensure a safe power connection.
Once your machine is set up and assembled as previously described in this manual, it is ready to be connected to the power source.
Note About Extension Cords: Using an incorrectly sized extension cord may decrease the life of electrical components on your machine.
SB1023 110V (Prewired)
Required Power Source | 110V, | |
Full Load Amp Draw | 9.5 Amps | |
Phase | ||
Frequency | 60 Hz | |
Minimum Circuit Size | 15 Amps | |
Included Plug | NEMA | |
Minimum Extension Cord Size | 14 AWG | |
Maximum Extension Cord Length | 50 ft. |
SB1023 (220V Option)
Required Power Source | 220V, | |
Full Load Amp Draw | 5 Amps | |
Phase | ||
Frequency | 60 Hz | |
Minimum Circuit Size | 15 Amps | |
Recommended Plug/Receptacle | NEMA | |
Minimum Extension Cord Size | 16 AWG | |
Maximum Extension Cord Length | 50 ft. |
220V Conversion for SB1023
Wiring diagrams are provided in the back of this manual (Page 36) showing the Model SB1023 wired for both 110V and 220V. Refer to these diagrams when following this procedure. Additionally, you must purchase the 220V conversion kit in order to complete the conversion. Call our parts department at
(417)
To convert the Model SB1023 to operate on
220V power:
1.DISCONNECT MACHINE FROM POWER!
2.Rewire the motor for 220V, as shown in the diagram on the inside of the motor junction box. If there is not a diagram in the junction box, use the diagram in this manual (Page 36).
3.Replace the contactor on the machine with the contactor from the 220V conversion kit. Set the amp dial to 5.5A
4.Replace the power cord plug with a NEMA