P R E P A R A T I O N

 

13" Heavy 13® Gearhead Lathe

For Machines Mfg. Since 5/11

 

 

 

Grounding Requirements

This machine must be grounded! In the event of certain types of malfunctions or breakdowns, grounding provides a path of least resistance for electric current in order to reduce the risk of electric shock.

Improper connection of the equipment-grounding wire can result in a risk of electric shock. The wire with green insulation (with or without yellow stripes) is the equipment-grounding wire. If repair or replacement of the power cord is necessary, do not connect the equipment- grounding wire to a live (current carrying) terminal.

Check with an electrician or qualified service personnel if you do not understand these grounding requirements, or if you are in doubt about whether the machine is properly grounded. If you ever notice that a cord is damaged or worn, disconnect it from power, and immediately replace it with a new one.

The power cord and plug specified under Circuit Requirements section on the previous page has an equipment-grounding wire and a grounding prong. The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances (see Figure 9).

Extension Cords

We do not recommend using an extension cord with this machine. If you must use an extension cord, only use it if absolutely necessary and only on a temporary basis.

Extension cords cause voltage drop, which may damage electrical components and shorten motor life. Voltage drop increases as the extension cord size gets longer and the gauge size get smaller (higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following requirements:

Minimum Gauge Size

12 AWG

Maximum Length (Shorter is Better)

50 ft.

GROUNDED

L6-30 LOCKING

RECEPTACLE

Grounding Prong

is Hooked

L6-30

LOCKING

PLUG

Current Carrying Prongs

Figure 9. Typical NEMA L6-30 plug and receptacle.

-18-

Page 24
Image 24
Southbend SB1049F owner manual Grounding Requirements, Extension Cords