Appendix A — Wiring Requirements

Note the following cabling requirements before connecting the equipment. If these limits (which are the same ones that apply to our current SPIRIT System) are exceeded, the ConnecT/R may not work properly.

The total wiring length from the controller to the SPIRIT Telephone cannot exceed a total of 1000 feet of 24-gauge DIW (twisted-pair copper) wire or 22-gauge D station wire, plus 25 feet of 4-wire line cord.

The total wire length from the controller to the telephone device cannot exceed a total of 1000 feet of 24-gauge DIW (twisted-pair copper) wire or 22-gauge D station wire, plus 25 feet of 4-wire line cord.

If the ConnecT/R is installed outside the building where the controller is located, or away from the building where the attached SPIRIT Telephone is located (using exposed wiring), In-Range/ Out-of-Building protec- tors (IROB TII Model 371 or ITW Model SP69073, AT&T order number 31304) must be installed by a qualified technician.

Contact your AT&T representative for additional information.

If the telephone device will be in a building other than where the ConnecT/R is located, a Block Protector must be installed by a qualified technician (one Block Protector for each "remote" telephone device). Order an AT&T Model 4C1S (comcode 104386545). In addition, you will need a Building Entrance Protector, which can house up to six 4C1S Block Protectors. Order Model 110ANA1-06 (comcode 105736482). Contact your AT&T representative for additional information.