HTMA REQUIREMENTS
|
|
| TOOL CATEGORY |
| |
| HYDRAULIC SYSTEM |
|
|
|
|
| REQUIREMENTS | TYPE 1 | TYPEII | TYPEIII | TYPE RR |
|
|
|
|
|
|
| FLOW RATE | ||||
| TOOL OPERATING PRESSURE | ||||
| 2000 psi | 2000 psi | 2000 psi | 2000 psi | |
| (at the power supply outlet) | (138 bar) | (138 bar) | (138 bar) | (138 bar) |
|
|
|
|
|
|
| SYSTEM RELIEF VALVE SETTING | ||||
| (at the power supply outlet) | ||||
|
|
|
|
|
|
| MAXIMUM BACK PRESSURE | 250 psi | 250 psi | 250 psi | 250 psi |
| (at tool end of the return hose) | (17 bar) | (17 bar) | (17 bar) | (17 bar) |
| Measured at a max. ß uid viscosity of: | 400 ssu* | 400 ssu* | 400 ssu* | 400 ssu* |
| (at min. operating temperature) | (82 centistokes) (82 centistokes) (82 centistokes) (82 centistokes) | |||
|
|
|
|
|
|
| TEMPERATURE | 140¡ F | 140¡ F | 140¡ F | 140¡ F |
| SufÞ cient heat rejection capacity | (60¡ C) | (60¡ C) | (60¡ C) | (60¡ C) |
| to limit max. ß uid temperature to: |
|
|
|
|
| (at max. expected ambient temperature) |
|
|
|
|
| Min. cooling capacity | 3 hp | 5 hp | 7 hp | 6 hp |
| at a temperature difference of | (2.24 kW) | (3.73 kW) | (4.47 kW) | (5.22 kW) |
| between ambient and ß uid temps | 40¡ F | 40¡ F | 40¡ F | 40¡ F |
| NOTE: | (22¡ C) | (22¡ C) | (22¡ C) | (22¡ C) |
|
|
|
|
| |
| Do not operate the tool at oil temperatures above 140¡ F (60¡ C). Operation at higher temperatures can cause operator | ||||
| discomfort at the tool. |
|
|
|
|
|
|
|
|
|
|
| FILTER | 25 microns | 25 microns | 25 microns | 25 microns |
| Min. | 30 gpm | 30 gpm | 30 gpm | 30 gpm |
| Sized for ß ow of at least: | (114 lpm) | (114 lpm) | (114 lpm) | (114 lpm) |
| (For cold temp. startup and max. |
|
|
|
|
|
|
|
|
|
|
| HYDRAULIC FLUID | ||||
| Petroleum based |
|
| ||
| (premium grade, |
|
|
|
|
| VISCOSITY |
|
|
|
|
| (at min. and max. operating temps) |
|
|
|
|
| NOTE: |
|
|
|
|
| When choosing hydraulic ß uid, the expected oil temperature extremes that will be experienced in service determine the | ||||
| most suitable temperature viscosity characteristics. Hydraulic ß uids with a viscosity index over 140 will meet the require- | ||||
| ments over a wide range of operating temperatures. |
|
|
|
|
|
|
|
|
|
|
| *SSU = Saybolt Seconds Universal |
|
|
|
|
NOTE: |
|
|
|
|
These are general hydraulic system requirements. See tool SpeciÞ cation page for tool speciÞ c requirements.
10