CHARGING THE ACCUMULATOR
The tools required to charge the breaker accumulator | NOTE: | |
are the Charge Hose assembly (505232) and the Ac- | When disengaging the tester a “POP” of nitrogen is | |
cumulator Tester (28257), which are used with other | ||
normal. | ||
Stanley model breakers. When charging the accumula- | ||
6. Connect the charge hose assembly to the charg- | ||
tor, make sure the tools and charge valve is clean. Dirt | ||
can contaminate the charge valve and cause leakage. | ing valve on the tester. Make sure the valve on the | |
1. Remove the protective plug from the accumulator | charge hose assembly is closed. Open the valve on | |
the nitrogen bottle. | ||
charge valve. | ||
7. Very slowly open the valve on the charge hose as- | ||
2. Hold the chuck end of the tester and turn the gauge | ||
sembly and slowly meter the nitrogen into the break- | ||
fully counter clockwise to ensure the plunger inside | ||
er charge valve until the tester reads the correct | ||
the chuck is completely retracted. | ||
charge pressure. | ||
3. Screw the tester into the breaker charge valve by | ||
8. When the correct pressure is obtained, close the | ||
turning the chuck. Do not use the gauge for turn- | ||
valve on the charge hose assembly and on the nitro- | ||
ing as this will advance the plunger in the chuck. | ||
gen bottle. Unscrew the gauge to retract the plung- | ||
Tighten the chuck lightly against the breaker charge | ||
er. Loosen and remove the tester from the charge | ||
valve. | ||
valve. Before replacing the protective plug, inspect | ||
| ||
4. Turn the gauge clockwise to advance the plunger | the plug | |
until a pressure is indicated on the gauge. Do not | the plug. Apply Loctite™ 242 to plug and cap. | |
overtighten. |
|
5.If the pressure is correct, unscrew the gauge to re- tract the plunger. Then, loosen and remove the tes- ter from the charge valve. If the pressure is not cor- rect, proceed to Step 6.
CHARGE PRESSURE SPECIFICATION
Main Accumulator: | 350 PSI +/- 10 PSI |
| 24 BAR |
Main Accumulator |
|
P/N 28257 Tester |
|
P/N 505232 Charge Hose Assy |
|
| MB656 User Manual ◄ 17 |