Stanley Black & Decker RW30 Troubleshooting, « on » TRANSLAMATIC‘s green light does not work

Models: RW30

1 40
Download 40 pages 45.27 Kb
Page 22
Image 22

TROUBLESHOOTING

 

The « ON » TRANSLAMATIC‘s green light does not work

 

PROBABLE CAUSE

CHECKS AND REMEDYS

 

« ON/OFF » switch

Check its good position and its good working

 

 

order

 

Alimentation’s cable cutted

Check the alimentation’s cable

 

Alimentation’s plug

Check the alimentation’s plug

 

Alimentation’s fuse or circuit breaker

Check the primary alimentation

 

The « ON » TRANSLAMATIC‘s green light works but the Charlie box does not work

 

PROBABLE CAUSE

CHECKS AND REMEDYS

 

Link cable between the TRANSLAMATIC and

Check the connexions or/and change the cable

 

the Charlie box

 

 

Charlie box’s fuse

Check the fuse

 

Respect the « ON »process order

Put « ON » the Translamatic before putting the

 

 

Charlie box “ON”.

 

Charlie box

Try with another Charlie box

 

Interface card

Check if the interface card alimentation’s green

 

 

light is alight during the cycle. Call our After

 

 

Sales Dpt

 

Stabilized alimentation out of service

Check the alimentation’s tension, normally 27V in

 

 

CC.

 

 

Call our After Sales Dpt

 

The welding support head does

not move on one or several axis

 

PROBABLE CAUSE

CHECKS AND REMEDYS

 

Charlie box

Try with another Charlie box

 

Charlie box keyboard

Check the good working order of the keyboard’s

 

 

contacts. Check the good working order of the

 

 

keyboard using it in the test mode for example.

 

 

Call our After Sales Dpt

 

Interface card

Check the connexions

 

 

Check if the card’s lights are alight during a

 

 

moving command. Call our After Sales Dpt

 

Axis engine’s cards

Check if the card’s lights are alight during a

 

 

moving command.

 

 

Switch the connexions between the 2 engines and

 

 

the recheck the moving of the torch (the

 

 

movements are reversed)

 

 

Call our After Sales Dpt

 

Translation’s screw mechanically blocked

Check if the screw is not top-blocked on the stop

 

 

bumpers or on the ball bearing or on the cardan.

 

 

Unscrew manually the screw if it is possible.

 

 

Call our After Sales Dpt

 

Uncontrolled speed of the torch and/or

no high speed and/or speed not as usual.

 

PROBABLE CAUSE

CHECKS AND REMEDYS

 

Charlie box

Try with another Charlie box

 

 

Change the Charlie box card

22 - RW30 USER MANUAL

 

Page 22
Image 22
Stanley Black & Decker RW30 user manual Troubleshooting, « on » TRANSLAMATIC‘s green light does not work