TROUBLESHOOTING
| Coder’s pulses defect | Check the coder connexion on the right side and |
| ||
|
|
| on the bottom of the interface card (J3 connector |
| |
|
|
| side). |
| |
|
|
| Replace the interface card. |
| |
| Axis engine’s cards | Check if the card’s lights are alight during a |
| ||
|
|
| moving command. |
| |
|
|
| Switch the connexions between the 2 engines and |
| |
|
|
| the recheck the moving of the torch (the |
| |
|
|
| movements are reversed) |
| |
|
|
| Call our After Sales Dpt |
| |
| Interface card | Check all the connexions |
| ||
|
|
| Check if the card’s lights are alight during a |
| |
|
|
| moving command. |
| |
|
|
| Replace the interface card |
| |
|
|
| Call our After Sales Dpt |
| |
| Couple Engine + Coder. | Replace the couple Engine + Coder. |
| ||
|
| No wire | feeding |
|
|
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| ||
| The PGA | Close or set up the wire’s pressure with the PGA’s |
| ||
|
|
| rollers. |
| |
| The Roll n’ Roll | Check the wire’s drum and/or set the Roll n’ Roll |
| ||
|
|
| brake |
| |
| Cables | Check the connexions and the PGA‘s alimentation |
| ||
|
|
| cable |
| |
| Charlie box | Try with another Charlie box |
| ||
|
|
| Check if the welding command light is alight on |
| |
|
|
| the interface card |
| |
| Link cable between the TRANSLAMATIC and | Check the connexions or/and change the cable |
| ||
| the Charlie box |
|
|
| |
| Welding trigger opened (Welding control | Check the closing of the welding trigger with an |
| ||
| connector) | ohmeter (value < to 20 ohms) between the pins 3 |
| ||
|
|
| and 4 of the 7 points connector or C an D of the |
| |
|
|
| Amphenol connector 19 points. |
| |
| Stabilized alimentation out of service | Check the alimentation’s tension, normally 27V in |
| ||
|
|
| CC. |
| |
|
|
| Call our After Sales Dpt |
| |
|
| Wire feeding OK but no welding |
|
| |
| PROBABLE CAUSE | CHECKS AND REMEDYS |
| ||
| Ground cable | Make sure that the ground cable is well connected |
| ||
| Interface card | Check if the card’s lights are alight during a |
| ||
|
|
| moving command. |
| |
|
|
| Call our After Sales Dpt |
| |
| Arc welder generator | Check the parameters and the good operating of |
| ||
|
|
| the arc welder |
| |
|
|
| Call our After Sales Dpt |
| |
|
|
| RW30 USER MANUAL - 23 |