LED STATUS

PROBLEM

 

SOLUTION

 

 

Self diagnostic check has detected

1

Turn the power off for 10-20 seconds then on again to

 

 

 

 

 

clear these error codes.

 

 

 

 

 

a problem with the gas valve driver

 

 

 

 

 

 

 

circuit, internal microprocessor, or

2

If any of these error codes persist or cannot be cleared

 

 

other internal circuits.

 

 

 

- replace the gas control valve/thermostat.

 

 

 

 

 

 

 

1

Turn the power off for 10-20 seconds then on again to

 

 

 

 

 

The gas control valve/thermostat

 

clear these error codes.

 

 

 

 

 

has sensed main burner flame out

 

 

 

 

of proper sequence.

2

Replace the gas control valve/thermostat if this error

 

 

 

 

 

 

code persists.

 

 

Water temperature in the tank has

1

Turn the power off for 10-20 seconds then on again to

 

 

 

clear these error codes.

 

 

exceeded 195° F and has activated

 

 

 

 

 

 

 

the ECO (energy cut off) high

2

Replace the gas control valve/thermostat if the error

 

 

temperature limit.

 

 

 

code persists.

 

 

 

 

 

 

 

1

Press and release both temperature adjust buttons

 

 

Self diagnostic check has detected

 

several times - cycle water heater power off and on.

 

 

 

 

 

that one or both of the temperature

 

 

 

 

adjust buttons are stuck.

2

Replace the gas control valve/thermostat if the error

 

 

 

 

 

 

code persists.

 

 

Self diagnostic check has detected

1

Turn the power off for 10-20 seconds then on again to

 

 

the water temperature sensor

 

clear these error codes.

 

 

 

 

 

(located in the control valve's

 

 

 

 

immersion probe) is either open or

2

Replace the gas control valve/thermostat if the error

 

 

 

 

shorted.

 

code persists.

 

 

 

1

Turn off power to the water heater. Ensure black

 

 

Self diagnostic check has detected

 

resistor wire is not cut, missing, and is installed

 

 

 

between pins 3 & 4 of ignitor assembly plug. Replace

 

 

a problem with black resistor wire

 

 

 

 

ignitor assembly if damaged or defective.

 

 

on the ignitor assembly plug;

 

 

 

 

 

 

 

resistor wire is open or shorted.

2

Replace the gas control valve/thermostat if the error

 

 

 

 

 

 

 

code persists.

 

 

Self diagnostic check has

1

Turn off power to the water heater.

 

 

 

 

 

 

determined resistance of the black

2

Replace the igniter assembly plug.

 

 

resistor wire on ignitor assembly

 

 

 

 

plug is not within tolerance.

3

Replace the gas control valve/thermostat if the error

 

 

 

 

code persists.

 

 

 

1

Ensure air pressure switch hose is not kinked or

 

 

 

 

clogged, ensure the blower housing is clear of any

 

 

 

 

condensation.

 

 

The gas control valve/thermostat

2

Check vent temperature limit switch - if it is determined

 

 

has detected the air pressure switch

 

that the vent temperature limit switch is opening its

 

 

circuit is opening repeatedly during

 

contacts at normal operating temperatures during

 

 

one heating cycle.

 

heating cycle - replace the vent temperature limit

 

 

 

 

switch.

 

 

 

3

Ensure water heater is not over-firing. Call the technical

 

 

 

 

support for further assistance.

 

 

 

 

 

31

Page 31
Image 31
State Industries GS675HRVIT, GS675YRVIT instruction manual LED Status Problem Solution

GS675HRVIT, GS675YRVIT specifications

The State Industries GS675HRVIT and GS675YRVIT are high-efficiency water heaters designed to meet the growing demand for reliable and energy-efficient hot water solutions. These models are ideal for both residential and light commercial applications, offering a blend of advanced technology, durable construction, and user-friendly features.

One of the standout characteristics of the GS675HRVIT and GS675YRVIT is their compact design, which makes them easy to install in various spaces without compromising performance. Both units are equipped with a high-efficiency gas burner that provides rapid water heating capabilities. Their power input allows for quick recovery rates, ensuring a steady supply of hot water when needed.

Energy efficiency is a key feature of these models. They utilize advanced insulation materials and designs that minimize heat loss, thus significantly reducing energy consumption. This not only contributes to lower utility bills but also supports environmental sustainability efforts by lowering carbon footprints. Both models are designed to meet or exceed Energy Star certification standards, highlighting their commitment to energy conservation.

In terms of technology, the GS675HRVIT and GS675YRVIT incorporate robust safety features, including a temperature and pressure relief valve that prevents dangerous pressure build-up, as well as an electronic ignition system that improves reliability by eliminating the need for a standing pilot light. Additionally, the gas control valve ensures precise regulation of the water temperature, enhancing safety and comfort for users.

Durability is another hallmark of these water heaters. Constructed with high-quality materials, the units feature a glass-lined tank that resists corrosion, extending the lifecycle of the product. They also come with a comprehensive warranty, providing peace of mind for consumers regarding their investment.

Users will appreciate the convenience that the GS675HRVIT and GS675YRVIT models offer, including easy-to-use controls and clear indicators for operational status. Installation and maintenance are simplified, making it straightforward for both homeowners and professionals to manage the unit over time.

Overall, State Industries GS675HRVIT and GS675YRVIT are excellent choices for anyone looking for efficient, reliable, and durable water heating solutions. With their innovative technology, energy-saving features, and user-friendly design, these models stand out in the competitive market of hot water heaters.