WATER HEATER CONTROL BOARD TROUBLESHOOTING AND DIAGNOSTIC LED INTERPRETATION

Conditions:

Power On

Red, heater control “Call for Heat” LED – on

Red, ignition control board diagnostic LED – Flashing

Note LED Flash Code before resetting heater.

LED Status

Indication

1

Flash

System is in lock out.

 

 

 

2

Flashes

Draft proving (pressure) switch failed to open within 5 seconds at the end of the last

 

 

cycle.

3

Flashes

Draft proving (pressure) switch failed to close ( -2.1 inches of water column pressure)

 

 

within 5 seconds after the inducer was started. The low gas pressure switch )closes

 

 

at 5.2" ± .04" w. c.) may have remained open (Nat Gas only.)

4 Flashes

Open on high temperature limit switch (ECO).

 

 

5 Flashes

Not Used

 

 

6 Flashes

115-volt supply power connection is indicating reversed polarity.

 

 

7 Flashes

Flame sensor reads a low flame signal for more than 4.25 sec.

 

 

 

8

Flashes

No ignition sensed.

 

 

Continuous Flash

Continuous flame sensed for more than 5 seconds without gas valve being energized.

 

 

Continuous ON

Internal control board failure.

*Control system self adjusts to use a minimum voltage for ignition. Lower voltage results in lower IGNITOR temperature which results in longer IGNITOR life. IGNITOR voltage may vary from Nominal 80 VAC.