State Industries SBN85 390 (A), SBD30 150 GAS Water Heater Service Handbook Test 2 Polarity Check

Models: SBN71 120 SERIES 108 SBD30 150 SBD30 199 SBN85 390 (A)

1 55
Download 55 pages 58.42 Kb
Page 36
Image 36

SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

TEST 2 – POLARITY CHECK

Conditions:

No hot water

Green “Power” LED is on. Tank is more than 5° F below temperature dial setting.

Red ignition control board diagnostic LED is flashing 6 times between pauses.

Red, diagnostic “Call for Heat” LED- OFF.

TEST 2

Polarity Check

Check from on/off switch center and white wire terminals to ground

115-125 VAC is not present

see Test 1.

 

 

Voltage is present white (right terminal) to ground but not

reverse supply wire connections - polarity is

black (center terminal) to ground

reversed.

State Water Heaters

35

Technical Training Department

Ashland City, Tennessee © 2007

 

 