State Industries SBD30 150, SBN85 390 (A), SBN71 120 Water Temperature Circuit Check Continuity

Models: SBN71 120 SERIES 108 SBD30 150 SBD30 199 SBN85 390 (A)

1 55
Download 55 pages 58.42 Kb
Page 45
Image 45

SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

TEST 11 - WATER HEATER SHUTTING OFF BELOW SETTING

Conditions:

Main burner ignited

Stored water is below temperature setting more than 5° F (Tank Average).

Power off

Plug disconnected from heater control board receptacle E3 and E4

TEST 11

WATER TEMPERATURE CIRCUIT CHECK - CONTINUITY

If…

 

then

continuity check pin to pin of lower

See Test 4

temperature probe shows 1 or 0 (E4)

Check wiring and plug connections to heater

 

 

control board receptacle E4

 

 

Replace lower temperature probe

continuity check red wire pin to red wire pin

see Test 4

on upper temperature sensor shows 1 or 0 (E3)

Check wiring and plug connections to heater

 

 

control board receptacle

 

 

Replace upper temperature probe

All above checks are okay

Replace the water heater control.

 

 

 

State Water Heaters

44

Technical Training Department

Ashland City, Tennessee © 2007

 

 