State Industries SBN71 120, SBD30 150, SBN85 390 (A) manual Test Ignitor Heats No Main Burner

Models: SBN71 120 SERIES 108 SBD30 150 SBD30 199 SBN85 390 (A)

1 55
Download 55 pages 58.42 Kb
Page 42
Image 42

SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

..............TEST 8 – IGNITOR HEATS

NO MAIN BURNER

24 V.

E1 PLUG TO

PIN 9

E1 PLUG TO

PIN 12

TEST 8

......IGNITOR HEATS

NO MAIN BURNER

 

 

 

 

 

 

 

If

 

then

 

 

 

 

 

 

 

 

short heat up time of IGNITOR

 

Check control box grounding.

 

 

 

 

Normal (Approximate 20 seconds) warm up - no ignition

Check for 24V from E1, Pin 12 to ground during 4 second trial.

 

 

........Yes - Continue

No - Replace Ignition Board

No voltage present E4, Pin 12 to ground

 

Replace ignition board

 

 

 

 

 

24 Volt was present from E1, Pin 12 to ground, but no

Check that air has been purged from gas circuit

check that

main burner

 

wiring and connections to gas valve and E1, Pin 9 are correct

 

 

.........check for 24 VAC at E1, Pin 9 to ground during 4 second

 

 

trial for ignition.

 

 

 

State Water Heaters

41

Technical Training Department

Ashland City, Tennessee © 2007

 

 

Page 42
Image 42