State Industries SBD30 199, SBD30 150, SBN85 390 (A), SBN71 120 Model SBN 85-366NE, SBN 85-390NE

Models: SBN71 120 SERIES 108 SBD30 150 SBD30 199 SBN85 390 (A)

1 55
Download 55 pages 58.42 Kb
Page 18
Image 18

SBN71-120 thru 85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

VENT TABLES FOR CATEGORY I - TYPE B GAS VENT

Model: SBN 85-366NE, SBN 85-390NE

Input:366,000/399,000 Btu/hr.

 

 

 

Total Vent Height (feet)

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Connector Size: 6”

 

6

8

 

10

15

20

30

50

100

 

 

 

 

 

 

 

 

 

 

 

 

Input Btu/hr

Rise

Vent Connector Diameter (inches)

 

366,000

1'

9

9

 

9

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

 

399,000

10

9

 

9

9

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

366,000

2'

9

9

 

8

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

 

399,000

9

9

 

9

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

366,000

3'

9

8

 

8

8

8

8

8

8

 

399,000

9

9

 

8

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of Units

Combined Input (Btu/hr x 1,000)

Combined Vent/Manifold Diameter

 

 

 

 

 

 

 

 

 

 

 

 

2

732,000

 

12

10

 

10

9

9

9

8

8

 

 

 

 

 

 

 

 

 

 

 

798,000

 

12

12

 

10

10

9

9

8

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1,098,000

 

14

14

 

14

12

12

10

9

9

 

 

 

 

 

 

 

 

 

 

 

1,197,000

 

14

14

 

14

12

12

10

10

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

1,464,000

 

16

16

 

14

14

14

12

12

10

 

 

 

 

 

 

 

 

 

 

 

1,596,000

 

16

16

 

16

14

14

12

12

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State Water Heaters

17

Technical Training Department

Ashland City, Tennessee © 2007

 

 

Page 18
Image 18
State Industries SBD30 199, SBD30 150, SBN85 390 (A), SBN71 120, SERIES 108 manual Model SBN 85-366NE, SBN 85-390NE