SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

.......TEST 9 – IGNITOR HEATS

NO MAIN BURNER

Conditions:

Test 8 completed then:

Turn off power

Disconnect wires from gas valve

TEST 9

IGNITOR HEATS – NO MAIN BURNER

If…

then

 

Meter reads 0 or 1

Check meter scale setting to read between 550 and 650 Ohms

 

Replace Gas Valve

Meter indicates pilot and main coil have

Valve should be okay still no gas to main burner, then coil....

continuity

may be stuck

Replace Gas Valve

State Water Heaters

42

Technical Training Department

Ashland City, Tennessee © 2007

 

 