Sterling 882.00295.00 specifications Regeneration Heater Box Assembly

Models: 882.00295.00

1 72
Download 72 pages 46.88 Kb
Page 63
Image 63
Figure 17: Regeneration Heater Box Assembly

1.Access the desiccant canisters by removing the panels on the dryer.

2.Remove the Regeneration Heater Cover.

3.Unscrew the six (6) screws on the Heater Element Mounting Plate.

4.Slide out the heater assembly, taking care to not damage the gaskets.

5.Unscrew the heater loops that need to be replaced.

6.Re-install the new heaters. Securely tighten all fasteners.

Caution! The heater loops should not touch each other. This will create "hot spots" and lead to premature heater failure.

7.Insert the heater assembly back into the desiccant canister.

8.Fasten the six (6) screws on the Heater Element Mounting Plate.

9.Re-secure the Regeneration Heater Cover.

10.Re-install the dryer panels.

Figure 17: Regeneration Heater Box Assembly

Regeneration

Heater Cover.

Heater Element

Mounting Plate.

Viewing Glass, for

checking the status of the desiccant inside.

High

Temperature

Gaskets.

Stainless Steel

Hollow Core

Desiccant Tank

High

Temperature

Gaskets.

Regeneration

Heaters

Access cover can be removed in order to replace desiccant.

Desiccant Tank

Mounting

Platform

Large Dehumidifying Dryers

Maintenance

63