Sterling RF-30, RF-60 Vent, Maximum Number, Maximum Horizontal, Minimum, Extension, D-06838A

Models: RF-30 RF-45 RF-75 RF-90 RF-60

1 32
Download 32 pages 53.62 Kb
Page 14
Image 14
Vent

Table 4 - Category I Horizontal Venting Requirements

 

Vent

Maximum Number

Maximum Horizontal

Minimum

Extension

Unit

Diameter

Elbows

Vent Length

Vertical Rise

Distance

Size

(in)

*

(Ft.)

(In.)

from Wall

 

 

 

 

 

 

30

4

1

4

12

36

 

4

1

8

18

36

 

4

2

4

12

36

 

4

2

8

18

36

 

 

 

 

 

 

45

4

1

10

18

36

 

4

2

5

18

36

 

5

2

10

12

36

 

 

 

 

 

 

60

5

2

10

12

36

 

 

 

 

 

 

75

5

2

10

24

36

 

 

 

 

 

 

90

5

1

10

24

24

 

5

2

10

36

24

 

 

 

 

 

 

*One elbow is required to make the vertical extension, See Figure 13.

Figure 13 - Category I Horizontal Venting Requirements

D-06838A

14

Page 14
Image 14
Sterling RF-30, RF-60, RF-90, RF-75, RF-45 Vent, Maximum Number, Maximum Horizontal, Minimum, Extension, D-06838A