STT 1600
Filter of the electrical cabinet |
Return air filter |
Regeneration air filter |
STT 1600
Return air filter/Regeneration air filter
Loosen the securing nut on the filter housing and remove the housing lid. Remove the return air filter/regeneration air filter.
Clean the filter cartridge with compressed air from inside to out or renew the filter. Never knock the filter cartridge on the floor.
Clean the filter housing. Use
Mount the lid and fasten the securing nut.
Close the panel.
F
&
Never operate the dryer without return air filter/regeneration air filter.
The dryer can’t be put into operation if the panel is not replaced.
Order number |
|
return air filter: | ID 86036 |
regeneration air filter: | ID 88226 |
|
|
Maintenance