Sterling STT 300 Dehumidified Air Dryer, Error and error correction, Error Bypass Flap

Models: STT 300

1 85
Download 85 pages 41.96 Kb
Page 42
Image 42
Excess Temperature Regeneration Heater

SM2-615

Dehumidified Air Dryer

Check the blower.

Vacuum sensor defective.

Temperature Measurement Regeneration Heater Defective

Check the cables and the sensor.

Check the power supply.

Short circuit check.

Excess Temperature Regeneration Heater

The regeneration temperature is too high.

Check the safety temperature limiter.

SterlingService.

Insufficient Temperature Regeneration Heater

The regeneration temperature is too low.

Check the regeneration heater.

The Safety Switch Regeneration Heater Has Been Actuated

Check the heater.

Check the fuses.

Short circuit check of the heater.

Error Bypass Flap

The bypass flap does not close or closes too slowly.

Check the bypass flap.

Error Valve Block

The valve block has not reached the proper position. The main switch is placed in the off position.

Check the position of the valve block. Press the “ACK” key and put the main switch in the on positi- on immediately. If the valve block has not reached the correct position within 1 minute, the main switch is again placed in the off position.

SterlingService.

Temperature Measurement Outgoing Air Defective

Check cables and sensor.

Temperature Measurement Return Air Defective

Check cables and sensor.

Excess Temperature Return Air

Check cables and sensor.

Check the return air cooler.

Error and error correction 4-7

Page 42
Image 42
Sterling STT 300 Dehumidified Air Dryer, Error and error correction, Excess Temperature Regeneration Heater