Sterling STT 300 Dehumidified Air Dryer, Error and error correction, Safety Switch Drying Heater

Models: STT 300

1 85
Download 85 pages 41.96 Kb
Page 43
Image 43
Temperature Measurement Drying Heater Defective

Dehumidified Air Dryer

Temperature Measurement Drying Heater Defective

Check cables and sensor.

Check the power supply.

Short circuit check.

Excess Temperature Drying Heater

The drying temperature is too high.

Check the safety temperature limiter.

SterlingService.

Insufficient Temperature Drying Heater

The drying temperature is too low.

Check the drying heater.

Safety Switch Drying Heater

Check the heater.

Check the fuses.

Short circuit check of the heater.

Temperature Measurement Heater Defective Hopper X

(X = number of the drying hopper) Check cables and sensor.

Check the power supply.

Short circuit check.

Excess Temperature Heater Hopper X

(X = number of the drying hopper)

The temperature of the hopper heater is too high.

Check the safety temperature limiter.

SterlingService.

Insufficient Temperature Heater Hopper X

(X = number of the drying hopper)

The temperature of the hopper heater is too low.

Check the hopper heater.

Safety Switch Heater Hopper X

(X = number of the drying hopper) Check the heater.

Check the fuses.

Short circuit check of the heater.

SM2-615

Error and error correction 4-8

Page 43
Image 43
Sterling STT 300 Dehumidified Air Dryer, Error and error correction, Temperature Measurement Drying Heater Defective