8.1. Mounting of the suction device for regeneration exhaust air
When plastics are dried which produce hazardous gases, environmentally sound disposal of the regeneration exhaust air must be provided. The throughput of the regeneration blower may not be changed.
It must be taken into consideration when installing a disposal system (e.g. exhaust system) that regeneration exhaust air is extremely humid. This may result in condensation water which must not enter the dryer again under any circumstances.
8.2. Connection of the air coolers (optional)
F
A return air cooler is generally required in cases in which the return air temperature is over 65 °C (149°F).
The return air cooler can be connected to a coolant circuit or the water mains network.
Observe the water flow with connection to water mains network. The coolant circuit must be di- mensioned acccordingly.
Remove the side panel of the dryer.
Connect the coolant intake line and coolant return line to the return air cooler.
Obeserve the flow direction of the coolant through the return air cooler.
Check the connections for leaks.
Mount the side panel.