Stovax 7116HC, 7106HC, 7105 Walls Next To A Hearth, Site Requirements, Requirement for the walls

Models: 7100 7104 7102 7120 7103 7117 7101 7116HC 7116lC 7119 7161 7127 7128 7106 7160 7163 7130 7162 7116 7113lC 7113 7114 7106lC 7105 7106HC

1 32
Download 32 pages 3.68 Kb
Page 17
Image 17
WALLS NEXT TO A HEARTH

SITE REQUIREMENTS

WALLS NEXT TO A HEARTH

Solid, non-combustible material e.g. masonry or concrete

150mm H minimum

C

Requirement for the walls Thickness W

C

150mm

minimum

 

 

 

 

PR7204

 

 

 

 

 

 

 

 

 

 

 

Position of Appliance & Hearth in relation to walls

Requirement for the walls

 

 

 

 

 

 

Distance of hearth from wall

Distance of Appliance to wall

Min thickness of Wall

Min height of wall

 

'C'

 

'W'

'H'

 

 

 

 

 

 

0mm

0mm - 50mm

200mm

Height of appliance + 300mm

 

 

 

 

Or

 

 

 

 

 

 

 

 

1200mm from the hearth (take largest

 

0mm

51mm - 300mm

75mm

dimension)

 

 

 

 

 

 

0 - 150mm

150mm +

75mm

1200mm

 

 

 

 

 

 

150mm +

300mm +

No Minimum Requirement

 

 

 

 

 

Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance. Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.