2. REMOVAL OF THE LOG GUARD

INSTALLATION INSTRUCTIONS

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

*5"

4502

 

 

6"

4602

 

 

Self tapping screw at rear

Seal flue collar with Fire Cement

PR7196

Seal Collar with Fire Cement

Self Tapping Screw

 

 

Tee

 

 

 

 

Size

Stovax Part No.

 

 

 

 

5"

4516*

 

 

 

 

6"

4616

 

 

 

Cap

PR7218

To chimney connection

600mm min

1000mm max unsupported

To chimney connection 3.FITTING AND REMOVAL OF THE FIREBRICKS as detailed in building regulations

Elbow with access cover

Size Stovax Part No.

5" 4512

 

 

6"

4612

 

 

 

 

7"

4712

 

 

 

 

 

 

Flue Pipe 915mm (3ft)

 

 

Size

Stovax Part No.

 

 

5"

4502*

 

 

6"

4602

 

 

7"

4702

 

 

 

 

600mm min

1000mm max unsupported

Manual background as detailed in building regulations

Elbow with access cover

 

 

Size

Stovax Part No.

 

 

5"

4512

 

 

6"

4612

 

 

 

 

 

 

 

 

7"

4712

 

 

 

 

 

 

Flue Pipe 915mm (3ft)

 

 

Size

Stovax Part No.

 

 

5"

4502*

 

 

6"

4602

 

 

 

 

 

 

7"

4702

 

 

 

 

PR7195

PR7193

2. REMOVAL OF THE LOG GUARD

1.3Rear flue pipe installation

• Insert a tee into the flue collar

The tee piece is used as cleaning access.

• Lift appliance into position

Take care not to damage the hearth finish.

Level using adjustable bolts, see picture 1

Connect tee to the chimney using flue pipe

Secure with self tapping screw

Seal the connecting joints

Do not use a 90˚ elbow to make this connection

The Flue must be installed in accordance with manufacturers instructions.

2.1 To remove the Log guard:

• Lift Log Guard clear of the supporting brackets

• Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

3.FITTING AND REMOVAL OF THE FIREBRICKS

3.1Remove the firebricks as part of the routine maintenance. This can be carried out without the use of tools.

3.2Allow the appliance to cool fully before removing firebricks.

3.3Take care when handling, as bricks can become fragile after use. Life span depends on the type of fuels burnt and the level of use.

Replace damaged bricks as soon as possible

3.4If your stove is fitted with 4 upper firebricks:

Remove the lower 2 bricks first

Remove the top bricks from the support rails