Stovax GAZCO Linea Balanced Flue Convector Fire Servicing Instructions, Servicing Requirements

Models: GAZCO Linea Balanced Flue Convector Fire

1 25
Download 25 pages 46.98 Kb
Page 15
Image 15
SERVICING INSTRUCTIONS

SERVICING INSTRUCTIONS

SERVICING / FAULT FINDING CHARTS

1. SERVICING REQUIREMENTS

This appliance must be serviced at least once a year by a competent person.

All tests must be serviced by best practice as described by the current CORGI recommendations.

1.1Before any test are undertaken on the appliance, conduct a gas soundness test for the property to ensure that there are no gas leaks prior to starting work.

1.2Before any tests are undertaken on the appliance it is also recommended to fully check the operation of the appliance.

1.3Special checks

1.3.1Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot

1.3.2Clean away any fluff or lint from under the burner

1.3.3Check that the spark gap on the pilot is correct

1.4Correct any faults found during the initial tests and then re- commission the appliance conducting the usual safety checks.

1.5Advise the customer of any remedial action taken.

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does the pilot light?

 

 

Is the control being

 

 

Will the pilot light

 

 

 

the gas turned on to the

 

 

 

thegas pressure correct?

 

 

Has the system got any air in it?

 

 

 

 

SYSTEM OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Yes

 

No

 

Yes

Yes

No

 

 

FUNCTIONALIGNITIONCHECK1

PILOTWILL NOT LIGHT

 

isthereEnsureno debris aroundassembly,thepilot whichetc.)soot,(e.g. could short the spark,cleanarea.the

 

Yes valve.theOperate spark?athereIs

UserConsult retry.andInstructions correctly?operated

pilotofalignmentCheck thechangehead,burnermatch?witha theChangelead.ignition

electrode 5.sectionParts,ReplacingSee

andtapisolationCheck

retry.meter,gasappliance?

andCorrectNo retry.

retry.andpipesgasthePurge

inblockageaisTherethe system, check thepoint,inlettestthe valve.andseatingmagCheck thermocouplecorrectleadsfor orientation,condition andconnection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEXTTHETOGO IGNITIONCHART, 2CHECKFUNCTIONAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is

 

 

 

Is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

Yes

 

 

 

No

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15