3. COMMISSIONING

INSTALLATION INSTRUCTIONS

INSTALLATION

2.15Replace the glass frame; ensure the top of the frame is hooked on the tabs at the top of the appliance and replace the nine screws with the three longest screws used in the bottom fixing holes. Tighten from the top down.

HAVE YOU PURGED THE GAS SUPPLY?

2.16Connect the gas supply to the isolation device using 8mm pipe. Connect a suitable pressure gauge to the test point and turn on the gas supply and check for leaks.

2.17Light the appliance and set it to maximum. Check the pressure corresponds to the data badge. Turn the gas off and replace the test point screw. Turn the gas on and check the screw for leaks.

THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 20 MINUTES.

3. COMMISSIONING

NOTE: THE HANDSET HAS BEEN FACTORY PROGRAMMED TO OPERATE THIS FIRE. IF THE HANDSET OR CONTROL UNIT HAS BEEN REPLACED, YOU MUST FOLLOW THE PROGRAMMING PROCEDURE.

3.1 Programming the handset

Section 3 must be read in total before trying to program the hand set. The sequence must be performed while the ON / OFF on the display is still flashing.

3.1.1Remove the two outer screws from the under side of the appliance, pull the cover forward and remove. See diagram 9.

9

AR1341

3.1.2Working under the appliance the control box is located on the left hand side. Using a pen or something similar push the switch to the Unlock 3.1 Programming the handset position. When viewed from underneath the ON position is towards the front of the appliance. See diagram 10.

10

3.1.3The remote handset must now be programmed. Push the ON / OFF button (11), the ON or OFF display will start flashing. Then

press the ON / OFF button (11), and the (Manual background) (10) and (Manual background) (13) buttons at the same time.

Immediately after press the SET button (12) once. See diagram 11.

26

 

 

6

 

 

 

 

 

 

 

1:

Flame display

 

 

 

 

 

 

 

7

 

 

 

 

 

4 5

2:

Celsius display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:

Temperature display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

1

4:

On display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5:

Off display

 

 

 

 

 

2

9

 

 

 

 

 

6:

Low battery display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 3

7:

Clock display

12

 

 

 

 

 

 

 

8:

Auto display

 

 

 

 

 

 

 

 

 

 

 

 

11

9:

Manual display

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10: UP button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11: ON/OFF button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12: SET button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13: DOWN button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR1665

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1.4The clock (7) will appear on the display. After a few seconds this will disappear.

3.1.5Finally push the switch back to the Locked Manual background position, towards the rear of the appliance. The remote should now be tuned to the control box.

3.1.6Replace the lower cover; ensure the tabs are located on the rear flange. Engage the front tabs at the side of the appliance and replace the two screws. Take extreme care as to not trap any cables when replacing the cover.

NOTE: IF A NEW HANDSET IS PURCHASED THE ABOVE PROCEDURE MUST BE REPEATED.

3.2Check flame picture.

3.3Check gas pressure.

14

Page 14
Image 14
Stovax GAZCO Linea Balanced Flue Convector Fire manual Commissioning, Programming the handset, Installation Instructions