Stovax GAZCO Linea Balanced Flue Convector Fire manual Ignition Lead, Magnetic Safety Valve

Models: GAZCO Linea Balanced Flue Convector Fire

1 25
Download 25 pages 46.98 Kb
Page 19
Image 19
8.IGNITION LEAD

SERVICING INSTRUCTIONS

REPLACING PARTS

7.2Disconnect the thermocouple from the gas valve. See diagram 8 arrow C.

8

C

AR1344

7.3Undo the thermocouple nut in the back of the pilot burner by half a turn. This will release the thermocouple.

7.4Disconnect the two leads noting the orientation. The lead with the red tape on is connected to the thermocouple spade nearest the gas valve. See diagram 9.

9

4.5v

AR1346

WHEN REPLACING WITH A NEW THERMOCOUPLE TAKE EXTREME CARE TO BEND THE NEW COMPONENT TO THE EXACT SHAPE AND TO KEEP THE CONNECTORS IN THE SAME ORIENTATION.

7.5When replacing the thermocouple into the pilot burner ensure the component is pushed fully into the hole. There is a stop on the thermocouple to set the height.

7.6Lock the retaining nut just enough to grip the thermocouple.

7.7Replace the lower panel.

8.IGNITION LEAD

8.1Remove the lower panel and pull the ignition lead off the electrode.

8.2Locate the ignition lead in the control box situated on the left-hand side of the appliance and disconnect it. See diagram 10

10

4.5v

AR1346

8.3Release the wires from the central white clip and carefully cut the cable ties. This will release the ignition lead. See diagram 11.

11

AR1344

8.4Replace with a new lead, replace with new cable ties and fit the wires back into the clip.

8.5Fit the cover and ensure no wires are trapped.

9.MAGNETIC SAFETY VALVE

9.1Turn the gas off at the isolation device.

9.2Remove the lower cover. See diagram 6

19

Page 19
Image 19
Stovax GAZCO Linea Balanced Flue Convector Fire manual Ignition Lead, Magnetic Safety Valve, Servicing Instructions