IGNITION FUNCTIONAL CHECK 2

IGNITION FUNCTIONAL CHECK 2

NO SPARK

Ensure there is no debris around the pilot assembly,

(e.g. soot etc.) which could short the spark, clean the area.

 

 

Consult the users

 

 

 

instructions, retry.

 

From Ignition Fault

No

Is the valve being

Yes

 

Finding Chart 1

 

operated correctly?

 

 

FLAME FAILURE FUNCTIONAL CHECK 3

PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE

Ensure there is no debris around the pilot assembly, (e.g. soot etc.) Check for fluff in the pilot aeration hole. See the diagram in Replacing Parts section.

Light the pilot using either the handset or the touch pad.

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the gap between

 

 

 

No

Check tab on pilot burner

electrode and

wood is not damaged. Either

thermocouple 4.0mm?

 

 

repair tab or replace pilot

 

 

 

 

 

burner & retry

 

Yes

 

 

 

 

 

 

 

 

 

 

With the pilot

running is the gas

pressure as stated on

the data badge?

No

No

Will pilot

Yes

 

stay alight?

 

No

Problem is with the

pipework or

fittings which lead to the fire. Correct and retry.

With the fire running

on full is the gas at the pressure stated on the data badge?

Yes

16

 

 

Has ignition lead

 

Yes

 

 

 

become detached or is

 

Correct and retry.

 

 

 

 

 

 

 

 

 

connection poor?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

Check handset batteries are OK.

 

 

 

 

 

 

 

 

Remove the electrode lead

 

 

Replace if required. Check handset

 

 

 

 

is on manual. Check if handset lock

Yes

and electrode. With insulated

 

 

 

 

is off. Check batteries to the control

pliers. Hold the tip 4.0mm from the

 

 

 

 

pilot pipework, is there a spark

 

 

unit. Replace if required. Retry with

 

 

 

 

 

 

 

handset and touch pad.

 

 

when the system is operated?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

Is the pilot flame of the

correct length? See

diagram 4, Replacing

Parts.

Yes

Is thermocouple in

its correct position

 

 

in pilot bracket? See

 

 

diagram 4,

 

 

Replacing Parts.

 

 

 

 

 

 

Yes

 

 

 

 

 

No

No

Run for 3 mins,

Yes

 

turn off, time interval

 

until mag unit shuts with

 

 

 

 

a click. Is this greater

 

than 7 seconds?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Correct the position.

 

 

 

 

 

 

 

 

No

Has the ignition lead

 

become detached from the

Yes

control box?

 

 

 

 

No

Replace the lead, retry.

No

Check, clean or FLAME FAILURE FUNCTIONAL CHECK 3 replace the pilot

injector.

Is the thermocouple No connection good in Manual background

back of valve?

Yes

Replace.

Tighten the

connection and retry.

Replace the electrode.

 

Replace the electrode

 

lead and retry.

 

 

 

 

 

SYSTEM OK