Stovax GAZCO Linea Balanced Flue Convector Fire manual Changing Between Gas Types, Replacing Parts

Models: GAZCO Linea Balanced Flue Convector Fire

1 25
Download 25 pages 46.98 Kb
Page 22
Image 22
13. CHANGING BETWEEN GAS TYPES

SERVICING INSTRUCTIONS

REPLACING PARTS

13. CHANGING BETWEEN GAS TYPES

In order to change between gas types it will be necessary to change the following items.

Main Injector

Main Burner

Pilot Injector

Control Valve

Control Box

Thermocouple ( NG to LPG only).

LPG to NG no change).

Data Badge

14. CONTROL BRACKET ASSEMBLY

NOTE: THIS ONLY NEEDS TO BE DONE IF ACCESS IS TO THE CONTROLS IS RESTRICTED.

14.1Remove the outer decorative front, refer to the instructions supplied with the front.

14.2Remove the lower cover. See diagram 6.

14.3Disconnect the gas pipe at the isolation device. See diagram 21 arrow B.

21

B

C

 

AR1344

A

E

E

 

14.4 Remove the glass frame. See diagram 22 arrow C.

22

 

C

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

C

C

 

AR1338

14.5Remove the main burner as described in section 2.

14.6Remove the injector locknut. See diagram 23.

23

AR1345

14.7Disconnect the touch pad from the harness. See diagram 21 arrow A.

14.8Disconnect the ignition lead from the electrode.

14.9Remove the thermocouple. See diagram 21 arrow C.

14.10Remove the pilot pipe and ensure the pilot injector is kept safe.

14.11Remove the two screws securing the control bracket from under the appliance. See diagram 21 arrow E.

14.12Tilt the front edge of the bracket down slightly and move the assembly to the right to disengage the injector. Rotate the left hand side forward and down to allow the removal of the injector from the side of the appliance. The assembly should now be free of the appliance.

14.13Reassemble in reverse order and check for gas leaks.

22

Page 22
Image 22
Stovax GAZCO Linea Balanced Flue Convector Fire Changing Between Gas Types, Control Bracket Assembly, Replacing Parts