INSTALLATION INSTRUCTIONS
INSTALLATION
8
AR1157
6.7Coil up the surplus cable and locate in the back of the firebox.
NEVER SHORTEN THE CABLES, THEY WILL BE REQUIRED WHEN SERVICING THE APPLIANCE.
6.8Replace the lower cover plate.
Note: The cable adjuster may need to be tucked upward in order to fit the lower cover plate.
B) SCREW FIXING METHOD
6.9Alternatively, this appliance can be secured back to the fireplace opening using the screws and rawl plugs provided. Place the firebox centrally in the opening and mark the positions of the 4 fixing holes. Drill the holes and insert the 4 rawl plugs. See diagram 9
9
AR1375
6.10Offer the firebox into the opening and ensure that the gas supply pipe passes through the rubber seal.
6.11Refit the burner assembly and secure the 5 pozidrive screws. Connect the gas supply to the inlet connection on the burner unit and tighten. It may be necessary to support the inlet connection with another spanner whilst tightening this joint. See diagram 10.
6.12Turn on the gas supply to the appliance and check for leaks. Light the fire and check all joints on the appliance for leaks.
6.13Remove the sealing screw from the inlet connection and connect a suitable “U” gauge manometer. Light the fire and turn to the maximum position, refer to the data badge and ensure that the running pressure is correct. If the pressure varies significantly from that on the data badge, this may indicate a supply problem and will require immediate attention.
10
6.14Turn the appliance off, disconnect the “U” gauge and replace the sealing screw. Relight the appliance and check the sealing screw for leaks.
7.FITTING THE DECORATIVE INNER panel
7.1By rotating the panel, insert into fire box, Diagram 11.
11
AR1880
7.2Check that the panel is sitting behind the rear ledge, but in front of the spacer bracket so that it locates in the slot, Diagram 12.
12
AR1930
7.3Secure the panel using the two upper brackets and the pozidrive screws, Diagram 13. Use only the rearmost hole in the retaining bracket on each side.
18