A gas supply line of 3/4" (19) rigid pipe must be provided to the gas module. If local codes permit, a certified, 3'

WOLF INTEGRATED MODULES

Planning Information

GAS SUPPLY

A gas supply line of 3/4" (19) rigid pipe must be provided to the gas module. If local codes permit, a certified, 3'

(.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the units 1/2" NPT female inlet to the gas supply line.

When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.

Wolf natural gas modules will function up to 10,250' (3124 m) in altitude without adjustment and LP gas modules will function up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.

GAS SUPPLY REQUIREMENTS

NATURAL GAS

 

Gas Supply Pressure

5" (12.5 mb) WC

Min Line Pressure

7" (17.5 mb) WC

Max Pressure to Regulator

14" (34.9 mb) WC, .5 psi (3.5 kPa)

LP GAS

 

Gas Supply Pressure

10" (25 mb) WC

Min Line Pressure

11" (27.4 mb) WC

Max Pressure to Regulator

14" (34.9 mb) WC, .5 psi (3.5 kPa)

OVENS / WARMING DRAWERS

COOKTOPS

RANGES / RANGETOPS

OUTDOOR GRILLS

VENTILATION

wolfappliance.com 55